Diamond sensors

Sensor selection guide

DIAMSENS offers a range of multi-sensor modules. Each sensor is characterized for the usage conditions corresponding to a particular application. Our first module is dedicated to dosing applications for pool care products. Other specialized modules for agriculture, animal husbandry, wastewater treatment, etc… are coming soon

Diamond water quality pool sensor
Water Filtration
Electrochemical sensor for water quality monitoring
Sensor for testing water in a wastewater treatment plant
Drinking water test sensor
Aquaculture sensor: water quality testing
Fertirrigation : capteur pour le traitement de l'eau

Swimming Pool

Poultry farming watering: sensor for water treatment

Livestock Watering

Treatment and Distribution of Drinking Water: Sensor for Water Treatment

Drinking Water Treatment and Distribution

Fertigation: sensor for water treatment

Fertigation

Monitoring of natural environments: sensor for water treatment

Natural Waterways Monitoring

Soil analysis: sensor for water treatment

Water In Soil Analysis

Aquaculture: sensor for water treatment

Aquaculture

Wastewater treatment plant: sensor for water treatment

Industrial or "inspired by nature" wastewater treatment

Custom sensor

Sensor or Module On-Demand Customization

Sensors for swimming pools

Why control pool water?

It is important to make sur that the concentration of disinfectant is high enough to prevent the growth of bacteria and microalgae, while maintaining the pH at a level that does not cause eye or skin irritation.

 

Swimming pool water control sensor

Limitations of conventional probes

End users are not accustomed to cleaning and recalibrating probes according to the manufacturer’s recommendations. Very quickly the accuracy of the measurements will drift.

Conventional probes are relatively fragile (glass tube most often)

Conventional probes should be kept in a specific solution during the winter season.

Specific chlorine and/or bromine probes are generally unaffordable for an individual (a few hundred euros, or even more than a thousand euros). It is usually a measure of the redox potential that allows the chlorine concentration to be extrapolated, with highly fluctuating accuracy.

Diamond water quality pool sensor

The advantages of DIAMSENS diamond sensors

Innovative and sustainable diamond-based technology:

  • All-Solid Sensors
  • Sensors that can be stored in a dry place
  • Self-cleaning sensors
  • Direct measurement of chlorine (or bromine)

Diamond sensors: technical specifications


Measurement Range

Precision

Comments
Temperature

0 – 70°C

0,2°C

Conductivity

0 – 20 mS/cm

2%
pH

6 - 8

0,2 unité pH
Free Chlorine

0.5 – 10 ppm

0,2 ppm

Bromine
1 – 5 ppm
0,2 ppm
TDS
0 – 10 g/L
2%
Estimated from conductivity
TAC
0 – 10 g/L
2%
Estimated from conductivity
Standard combination
Temperature, conductivity, pH, free chlorine or bromine; estimation of TDS and TAC from conductivity.
Other combinations
According to needs

Standard modules and custom modules according to your needs

Other applications of DIAMSENS sensors

Drinking water test sensor

We are currently working on new applications

Diamond water quality pool sensor
Water Filtration
Electrochemical sensor for water quality monitoring
Sensor for testing water in a wastewater treatment plant
Drinking water test sensor
Aquaculture sensor: water quality testing
Fertigation: sensor for water treatment

Fertigation

Poultry farming watering: sensor for water treatment

Livestock Watering

Aquaculture: sensor for water treatment

Aquaculture

Monitoring of natural environments: sensor for water treatment

Natural Waterways Monitoring

Treatment and Distribution of Drinking Water: Sensor for Water Treatment

Drinking Water Treatment and Distribution

Wastewater treatment plant: sensor for water treatment

Industrial or "inspired by nature" wastewater treatment

Diamsens water quality sensor

Sensor or Module On-Demand Customization

Sensor developments

Depending on your needs, we can study the feasibility of a new measurement.

Special combination of sensors

We can assemble a new combination of pre-qualified sensors on our boards.

Characterization of sensors in a new environment

Before using a sensor under new conditions, it must be ensured that its behaviour will not be disturbed by chemical compounds that are present only under these conditions. In the case of strong interferents, a measurement of this interferent and compensation of the initial measurement should be considered.

Support for integration into equipment

Mechanical Integration

If modifications need to be made to our generic enclosure, or if an additional part needs to be designed to facilitate the integration of our enclosure into your equipment, our application engineers can coordinate the actions of our mechanic partners to provide you with a “tailor-made” solution.

Software Integration

If you don’t have the available resources, our application engineers can take care of this task.

Let's discuss your needs together